XR6/XR3 Installation Manual Connecting ac power
Page 5-2 Issue 3.0 2009-07-15
2. Connect the ac power ground to the station reference ground.
3. Verify that the station reference ground and the transformer ground terminal are connected
to the safety ground stud assembly on the rear of the transmitter, (see Figure 2.2 on page 2-3
and Step 3 - Step 4, page 4-1).
4. Verify that the ac power conductors are connected to the power transformer as shown in
Section 2, “Installing the power transformer” on page 2-1.
5. Optionally, install the NAX188 MOV ac transient protection system. See the NAX188
documentation for more information.