XR6/XR10 Installation Guide Digital Monitoring Products
15
COMPLIANCE
UL 1610 and 1076 SPECIFICATIONS
Central-Station and Proprietary Burglar-Alarm Units
17.1 Opening/Closing reports
The Opening/Closing Reports option must be programmed as YES. See the XR6/XR10 Programming Guide (LT-0230).
17.2 Automatic bell test
This option must be programmed as YES. See the XR6/XR10 Programming Guide (LT-0230).
17.3 Proprietary dialer
The Model XR6/XR10 provides Grade A proprietary service when configured as a digital dialer.
UL 1635 SPECIFICATIONS
Digital Burglar Alarm Communicator System Units
18.1 Digital Dialer telephone number
Both programmed telephone numbers must begin with a D or P. See the XR6/XR10 Programming Guide (LT-0230).
18.2 Entry delay
The maximum entry delay used must not be more than 60 seconds. See the XR6/XR10 Programming Guide (LT-0230).
18.3 Exit delay
The maximum exit delay used must not be more than 60 seconds. See the XR6/XR10 Programming Guide (LT-0230).
18.4 Test frequency
The Test Frequency option must be programmed so that the panel sends a report once every 24 hours. See the XR6/
XR10 Programming Guide (LT-0230).
18.5 Automatic bell test
This option must be programmed as YES. See the XR6/XR10 Programming Guide (LT-0230).
18.6 Grade B Central Station
Grade B Central Station service can be provided under UL 1635 by adding a Grade A local audible signal appliance and
placing the Model XR6/XR10 panel into the Model 350A Grade A Attack Resistant Housing.